1 Filtration
For ISO 14644 compliant environments Fan Filter Units (FFU) with H14 HEPA filters and G4 pre-filters provide 1,000m³/hour of filtered air. HEPA filtration can also be placed on the exhaust to provide BSL-3 compliance. For ceiling heights of 2.1m slimline FFUs are installed in the ceiling to provide vertical laminar flow. For ceiling heights of between 2.1m and 2.5m cleanrooms are horizontal flow.
2 HVAC
Typically, Cleancubes apply temperature control via a VRF (variable refrigerant flow) split system serving a plenum for cleanrooms or wall-mounted recirculating units for labs. Humidity control is also provided via upflow units or separate desiccant wheels. External condensers can be contained in attached plant rooms or mounted on the Cleancube exterior.
3 Environmental Monitoring
Saakvee provide fully integrated Environmental Monitoring Systems that can also be 21CFR Part 11 compliant. With a range of high-performance multifunction sensors, temperature, humidity and pressure can all be monitored in real time and recorded for an audit trail. Fully flush or semi flush LED displays give in-room feedback. We have a wide variety of options available.
4 Lighting
Powder-coated steel light units, flush mounted into the ceiling panels with drop-down hinged diffuser. Also available as surface-mounted aluminium LED batten luminaires for laboratories. Activation by switch or PIR (passive infrared) sensor. Lights can be UV filtered for photo sensitive processes.
5 Power Management
All models require a power connection from an external source. The rating of this will depend on the power demand of each module. UPS (uninterruptible power supply) battery back-up can also be provided and a changeover switch can be installed to alternate between a mains and generator supply.
6 Control Panel
15.7” touchscreen HMI+PLC provides a full control and monitoring system for the CleanCube. The Environmental Monitoring System feeds back to give real-time data on temperature, humidity and pressure. Fan speeds and HVAC systems can also be controlled as well as other compatible equipment.
7 Fire Alarm
In-room smoke detectors and audible and visual alarm beacons can be installed and linked back to a centralised fire alarm panel. This can be connected back to the main facility fire panel board if required.
8 Gas Services
Compressed air and other specialist gasses such as N2 and CO2 can be installed, with pipework in stainless 316 or Transair and connection to dedicated compressors, generators or cylinders.
9 Compressed Air & Nitrogen
Compressed air and nitrogen via compressors and generators housed directly within the cleanroom or lab – or in an enclosed plantroom. Pipework, point of use fittings, regulators and hook-up connections can also be put in place. Click the button below to visit the Klensys Cleanroom Hardware website and make a dedicated equipment broker service enquiry.
10 Extraction
Chemicals, airborne particulate and heat can all be extracted to a localised filtration unit for scrubbing. Safe change modules can also be placed on the exhaust system to mitigate the risk of cross-contamination.